TitleProduct

Huawei Router NE40E-X3

  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Guangdong

  • Validity to:

    Long-term effective

  • Last update:

    2019-12-09 10:27

  • Browse the number:

    315

Send an inquiries

Company Profile

Shenzhen Uonel Technology Co., Ltd

By certification [File Integrity]

Contact:kuyuekeji(Mr.)  

Email:

Telephone:

Phone:

Area:Guangdong

Address:Guangdong

Website:http://www.uonel-telecom.com/ http://kuyuekeji.foreturns.com/

Product Details

Overview


Table 1 Device attributes

Product Type

Description

BOM

Model

Earliest Software Version

NE40E-X3 DC

Integrated DC Chassis Components(NE40E-X3)-4U, Including Dual DC Power

02351596

CR52-BKPE-4U-DC

V800R007C00

NE40E-X3 AC

NE40E-X3 Integrated AC Chassis Components, (Including Dual AC Power)

02355250

CR5B0BKP0370

V800R007C00


Appearance

Figure 1 Appearance (DC)


Figure 2 Appearance (AC)


Components

Figure 3 Components (DC)



1. MPU

2. LPU

3. Cable tray

4. Rack-mounting ear

5. Air intake vent

6. Handle

7. DC Power module

8. Air filter

9. Ground terminal

10. Fan




Figure 4 Components (AC)




1. MPU

2. LPU

3. Cable tray

4. AC Power module

5. Rack-mounting ear

6. Air intake vent

7. Handle

8. Air filter

9. Ground terminal

10. Fan




Slot Layout

Figure 5 Slot layout


Table 2 Description of slot layout

Slot Name

Slot Quantity

Slot ID

Remarks

LPU

3

1 to 3

These slots hold LPUs.

MPU

2

4 to 5

These slots hold MPUs.


Interface Numbering

An interface is numbered in the format of slot number/card number/port number

 NOTE:
Slot number: The slots of LPUs are numbered from 1 to 3. The slot number increases from bottom to top, facing the front panel of the NE40E (there are corresponding marks on the panel).
Card number: The cards of LPUs are numbered from right to left and from bottom to top beginning with 0. If there is no card on a board, the card number is set to 0.
Port number: The ports of LPUs are numbered from top to bottom and from right to left beginning with 0.Technical Specifications of Huawei NE40E-X3


Item

Specification


Dimensions (H x W x D)

●DC: (4 U) 175 mm x 442 mm x 650 mm (6.89 in. x 17.40 in. x 25.59 in.)

●AC: (5 U) 220 mm x 442 mm x 650 mm (8.66 in. x 17.40 in. x 25.59 in.)

Weight (empty)

●DC: 12 kg (26.46 lb)

●AC: 20 kg (44.1 lb)

Weight (full configuration)

●DC: 42 kg (92.61 lb)

●AC: 52 kg (114.66 lb)

Cabinet installation standard

Can be installed in a standard 19" 800 mm-deep cabinet. A Huawei 2.2 m-high N68E cabinet is used by default.


Typical power consumption

●DC: 800 W (fully configured with LPUF-51s)

●AC: 950 W (fully configured with LPUF-51s)

●DC: 920 W (fully configured with LPUF-120s)

●AC: 1070 W (fully configured with LPUF-120s)


Typical heat dissipation

●DC: 2595.5 BTU/hour (fully configured with LPUF-51s)

●AC: 3082.2 BTU/hour (fully configured with LPUF-51s)

●DC: 2984.9 BTU/hour (fully configured with LPUF-120s)

●AC: 3471.5 BTU/hour (fully configured with LPUF-120s)

DC input voltage

●input voltage range: –38.4 V to –72 V

●input rated voltage: –48 V/ –60 V

AC input voltage

●input voltage range: 180 V to 264 V

●input rated voltage: 200 V to 240 V

MTBF

27.44 years

MTTR

0.5 hours

Availability

0.99999792

Slot quantity

5

Redundant MPUs

1:1

Redundant Switch fabrics

N/A

Redundant fans

Support for proper fan operation in case of a single fan failure for a short period at 40°C (104°F)

Redundant power supply

1+1

Forwarding performance

●225 Mpps (LPUF-51)

●360 Mpps (LPUF-120)

Switching capacity

1.08 Tbps


Operating temperature

●Long-term: 0°C to 45°C (32°F to 113°F)

●Short-term: –5°C to +55°C (23°F to131°F)

●Remark: Restriction on the temperature variation rate: 30°C/hour (86°F/h)

Storage temperature

–40°C to +70°C (–40°F to +158°F)

Relative operating humidity

●Long term: 5% to 85% RH, non-condensing

●Short term: 5% to 95% RH, non-condensing

Relative storage humidity

5% to 95% RH, non-condensing


Long-term operating altitude

<=4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature of the NEU100 must decrease by 1°C [33.8°F] for every 220 m [721.78 ft.].)

Storage altitude

Less than 5000 m (16404 ft.)

http://www.uonel-telecom.com/